KHD & GHL Doser 2.1 Slave Set, white, USA/CND

KHD & GHL Doser 2.1 Slave Set, white, USA/CND

$819.90

SKU: 1000-PL-1527 Category:

Description

GHL KH Director – Monitor, maintain, and control Alkalinity with ease

The upkeep of Alkalinity is the most important aspect of reef keeping. If you’re looking to achieve exceptional coral growth, Alkalinity testing is a must!

The KH Director is the result of more than 2 years of research and development into the automated Alkalinity monitoring and control department. As always, we’ve stuck to our fundamental belief in high quality and exceptional reliability to bring you a product that is built to last. Featuring a patent pending design, KHD utilizes lab grade quality test standards to provide precise results every time. KHD is built to provide aquarium hobbyists and professionals with a safe and reliable Alkalinity control product which presents great value, functionality, and practicality.

Automated Alkalinity monitoring and control

KH Director uses a modified pH probe to provide KH values. In terms of the KH test process, the 3 blue adapters on the KHD each connect to an available GHL Doser 2 or 2.1 dosing unit. One pump is used to feed tank water into the KHD. The second pump feeds the KHD with reagent fluid. The third pump extracts the test sample and used reagent fluid after a completed test, then dispenses it into a waste bin.

As tests occur, the 3 pumps automatically perform their assigned tasks and report the results onto a viewable data logging chart. This data is then viewable on myGHL, ProfiLux Touch, ProfiLux display, and additional external display unit.

Lab grade KH measurement accuracy

Measure your Alkalinity with lab-grade accuracy. With only a 100 ml water sample, KH Director® can provide measurement values with 0.1 ° dKH accuracy.

Extreme efficiency and cost-effectiveness

Here at GHL we understand the importance of on-going costs involved with automated KH monitoring and control. For the KH Director it was especially important to consider these costs and develop a highly-efficient, cost-effective product. A single 1000ml bottle of reagent can last for up to 3 months when testing is performed 4x per day at a KH value of 8.  The pH electrode used by the KH Director was specially designed for KH measurement and has an average lifespan of 1 – 2 years.

KH Director requirements

In order to operate the KH Director, you will need to have at least 3 available dosing pump motors. KH Director gives you the flexibility to run the device in one of two ways.

  • KHD can be connected to a Standalone Doser 2.1 or 2.0

  • KHD can be connected to a Slave Doser 2.1 or 2.0 and ProfiLux 3 or 4 controller

Seamless integration w/ GHL system

Through the use of the PAB (ProfiLux Aquatic Bus) connection, KH Director® seamlessly integrates into the modular GHL aquarium system. The PAB connection ensures interference free communication with other GHL PAB-devices such as the GHL Doser 2.1 or the ProfiLux® 4.

Backwards compatibility

We want you to grow with us! Even the ProfiLux 3 / 3.1 and GHL Doser 2.0 will be compatible with the KH Director.

What’s included

KH Director / Doser 2.1 set includes the following:

  • KH Director device w/ integrated measuring cell
  • Specially designed pH electrode for KH measurment
  • Calibration fluid
  • 500ml reagent bottle
  • Silicone hose
  • Power supply splitter cable
  • PAB-cable (50 cm / 19.6″ length)
  • GHL Doser 2.1 Slave, 4 pumps, white
  • 24V Power supply
  • 8x Plastic tubing adapters
  • 6ft USB cable